The Prevena Plus 125 Therapy Unit is a state-of-the-art medical device designed for managing closed surgical incisions and promoting wound healing through advanced negative pressure technology․
1․1 Overview of the Device and Its Purpose
The Prevena Plus 125 Therapy Unit is a portable, single-use negative pressure wound therapy (NPWT) system designed to manage closed surgical incisions and promote wound healing․ It uses advanced technology to create a controlled environment, reducing fluid accumulation and enhancing recovery․ The device is part of a comprehensive system, including a foam dressing and tubing, and is suitable for both clinical and home care settings․
1․2 Importance of Negative Pressure Wound Therapy (NPWT)
Negative Pressure Wound Therapy (NPWT) is a clinically proven method that facilitates healing by reducing fluid accumulation, promoting granulation tissue formation, and minimizing the risk of surgical site complications․ It is particularly effective for closed surgical incisions, enhancing recovery outcomes and reducing the likelihood of infection or dehiscence, making it a critical component in modern wound care management․
Components of the Prevena Plus 125 System
The system includes a portable therapy unit, foam dressing, tubing, and a fluid collection canister, designed to work together for effective wound management and healing support․
2․1 Therapy Unit Description
The Prevena Plus 125 Therapy Unit is a portable, lightweight device designed for closed surgical incisions, utilizing negative pressure to promote healing․ It features a user-friendly interface, LED indicators for status monitoring, and a rechargeable battery for convenience․ The unit is equipped with a pressure setting of -125mmHg and includes a Visicheck feature for dressing integrity․ Designed for up to 7 days of use, it supports wound recovery in a clinical or home setting․
2․2 Foam Dressing and Tubing
The foam dressing is a porous, adhesive pad placed directly on the surgical site to distribute negative pressure evenly․ The tubing connects the foam to the therapy unit, enabling the transfer of fluid and pressure․ Both components are single-use, ensuring sterility and safety․ The foam’s unique structure enhances wound drainage, while the tubing’s flexibility allows for patient mobility during therapy․ Proper placement is essential for optimal performance․
2․3 Canister for Fluid Collection
The canister is a disposable component attached to the therapy unit, designed to collect excess fluid from the surgical site․ It is connected via tubing to the foam dressing, enabling efficient drainage․ Regularly checking the fluid level is crucial to ensure proper function․ If the canister is full or blocked, it must be replaced promptly to maintain therapy effectiveness and prevent complications․ Proper handling ensures patient safety and system efficiency․ Always follow disposal guidelines for biohazardous waste․
Setting Up the Prevena Plus 125 Therapy Unit
Unpack and prepare the device, attach the foam dressing to the surgical site, and connect the tubing to the therapy unit for proper functionality and patient safety․
3․1 Unpacking and Preparing the Device
Start by carefully unpacking the Prevena Plus 125 Therapy Unit and its accessories, including the foam dressing, tubing, and canister․ Inspect all components for damage․ Ensure the therapy unit is fully charged or has adequate battery life․ Place the device on a stable, flat surface, away from direct sunlight․ Follow the user manual for initial setup and preparation before attaching it to the patient․
3․2 Attaching the Foam Dressing to the Surgical Site
Position the foam dressing over the surgical site, ensuring it is centered and evenly aligned․ Peel the backing from the dressing and gently press it onto the skin, smoothing out any air pockets․ Avoid applying tension on the tubing․ Check the dressing for proper adhesion and seal around the wound․ Refer to the user guide for detailed steps to ensure correct placement and secure attachment․
3․3 Connecting the Tubing to the Therapy Unit
Locate the connection port on the therapy unit and insert the tubing securely until it clicks․ Ensure the tubing is not kinked or pinched․ Attach the other end of the tubing to the foam dressing, making sure it is properly seated․ Check for any obstructions or twists in the tubing to maintain proper flow and pressure․ Confirm the connection is secure before turning on the device․
Operating the Prevena Plus 125 Therapy Unit
Turn on the device and set the recommended negative pressure․ Use the Visicheck feature to ensure proper sealing of the foam dressing․ Monitor the therapy unit’s operation, checking for alarms or error codes, and ensure the canister is not full․ Adjust settings as needed to maintain optimal therapy performance and patient comfort․
4․1 Turning On the Device and Setting Negative Pressure
Press and hold the power button to turn on the Prevena Plus 125․ Use the control panel to set the recommended negative pressure level․ Ensure the Visicheck feature confirms proper sealing․ Monitor the pressure gauge and adjust as needed․ The device will begin applying negative pressure to promote wound healing․ Always refer to the pressure settings prescribed by your healthcare provider․
4․2 Monitoring the Therapy Unit During Use
Regularly inspect the therapy unit for proper function․ Ensure the canister is not full and check for tubing kinks or blockages․ Verify the negative pressure setting and monitor alarm notifications․ If alarms sound, refer to the troubleshooting guide for resolution․ Proper monitoring ensures effective therapy and patient safety․ Always follow the manufacturer’s guidelines for optimal performance․
4․4 Understanding the Visicheck Feature
The Visicheck Feature provides visual confirmation of the therapy unit’s performance․ Press the ON/OFF button twice to activate․ One light indicates optimal seal, two lights suggest a good seal, and three lights signal a marginal seal․ If the seal is marginal, therapy effectiveness may be reduced․ Use this feature to ensure proper wound healing and system functionality at all times․
Monitoring and Maintaining the Therapy Unit
Regularly check the fluid level in the canister and inspect tubing for kinks or blockages․ Address any issues promptly to ensure proper therapy performance and patient safety․
5․1 Checking the Fluid Level in the Canister
Regularly inspect the canister to ensure it is not full․ If the fluid level is low, check for tubing kinks or blockages․ If the canister is full, turn off the unit and replace it as instructed․ Always monitor the fluid level to maintain proper therapy function and prevent alarms․ Address any issues promptly to ensure optimal performance and patient safety․
5․2 Identifying and Resolving Tubing Kinks or Pinches
Inspect the tubing regularly for kinks or pinches, which can obstruct fluid flow․ Gently straighten or reposition the tubing to restore proper function․ If a kink persists, check for blockages or sharp bends․ Ensure the tubing is securely connected to both the therapy unit and the foam dressing․ Addressing these issues promptly helps maintain consistent negative pressure and effective therapy outcomes․
5․3 Replacing the Therapy Unit as Needed
The Prevena Plus 125 Therapy Unit is designed for single-patient use and should be replaced as indicated by the manufacturer or healthcare provider․ Typically, the unit lasts up to 7 days for closed surgical incisions․ Replace the therapy unit if the canister is full, alarms persist, or the device shows signs of wear․ Always use a new unit to ensure proper function and maintain sterile conditions for effective wound healing․
Troubleshooting Common Issues
Troubleshooting the Prevena Plus 125 Therapy Unit involves addressing alarms, low battery, or blockage alerts․ Check fluid levels, ensuring the canister isn’t full, and inspect tubing for kinks or pinches․ Consult the user manual or contact technical support for unresolved issues to maintain proper device function and patient care․
6․1 Alarm Resolutions and Error Codes
The Prevena Plus 125 Therapy Unit alarms indicate issues such as low battery or high fluid levels․ Error codes guide troubleshooting steps․ The Visicheck feature aids in verifying proper operation․ For specific codes, refer to the user manual․ If issues persist, contact technical support․ Regular system checks help prevent alarms, ensuring uninterrupted therapy and optimal patient care․
6․2 Addressing Low Battery or Power Issues
If the Prevena Plus 125 Therapy Unit displays a low battery alert, ensure it is connected to a power source using the provided adapter․ Charge the device for at least 2 hours before reuse․ If issues persist, check the power cord for damage or loose connections․ For unresolved power problems, contact technical support at 1-800-275-4524 for assistance or replacement․
6․3 Handling Canister Full or Blockage Alerts
If the Prevena Plus 125 Therapy Unit alerts for a full canister or blockage, turn off the device and inspect the tubing for kinks or obstructions․ If the canister is full, replace it with a new one․ Ensure proper fluid drainage by checking for blockages in the tubing․ If issues persist, contact technical support for further assistance or replacement parts․
Disposal of the Prevena Plus 125 Therapy Unit
Dispose of the Prevena Plus 125 Therapy Unit according to local medical waste regulations․ Ensure proper handling of the canister and tubing to maintain environmental and safety standards․
7․1 Proper Disposal Methods
Dispose of the Prevena Plus 125 Therapy Unit responsibly by following medical waste guidelines․ Check the canister for fluid level, seal it securely, and discard with other biohazardous materials․ Recycle the therapy unit if local regulations permit․ Improper disposal may lead to environmental contamination or safety hazards․ Always adhere to healthcare facility protocols for safe and compliant disposal practices․
7․2 Environmental and Safety Considerations
Minimize environmental impact by recycling components when possible and properly disposing of biohazardous materials․ The Prevena Plus 125 is designed for safe use, with built-in features to prevent overfill and ensure patient safety․ Always follow local regulations for medical waste disposal to protect public health and the environment․ Proper handling prevents accidents and promotes eco-friendly practices․
Home Care and Patient Instructions
Patient guidelines emphasize proper Prevena Plus 125 usage, monitoring, and maintaining a clean environment․ The discharge kit provides essential accessories for seamless therapy continuation at home, ensuring safety and efficacy․
8․1 Patient Discharge Kit and Accessories
The Prevena Plus 125 Patient Discharge Kit includes the therapy unit, foam dressings, tubing, and a fluid collection canister․ Accessories like a power adapter and carrying bag are provided for portability․ The kit is designed for single-use NPWT, ensuring patients can continue therapy at home safely and effectively, with clear instructions for monitoring and maintaining the device․
8․2 Patient Guidelines for Using the Therapy Unit
Patient guidelines emphasize daily monitoring of the therapy unit, ensuring the canister is not full and checking for tubing kinks․ Patients should follow the provided instructions for operation, maintain proper hygiene, and avoid immersing the device in water․ Regular checks of the surgical site and surrounding dressing are essential to ensure effective therapy and prevent complications, promoting optimal wound healing outcomes․
8․3 Scheduling Follow-Up Appointments
Scheduling follow-up appointments is crucial for monitoring therapy progress and ensuring proper healing․ Patients should book appointments within 7 days of surgery to assess the surgical site and therapy unit function․ Regular check-ups help address potential issues early, ensuring optimal outcomes․ Patients are advised to keep all scheduled appointments to maintain effective therapy and resolve any concerns promptly․
Technical Support and Resources
For assistance, call 1-800-275-4524 or visit the official website for user manuals, guides, and FAQs․ Additional support resources include online tutorials and a dedicated customer service team․
9․1 Contact Information for Assistance
For immediate support, contact the Prevena Plus 125 customer service team at 1-800-275-4524․ This line is available 24/7 to address any technical or operational inquiries․ Additionally, visit the official 3M website for comprehensive resources and troubleshooting guides․ Patients and healthcare professionals can also access online FAQs and user manuals for detailed assistance․
9․2 Accessing User Manuals and Guides
The official 3M Prevena Plus 125 Therapy Unit user manuals and guides are available on the 3M website․ Visit the support section, navigate to the Prevena Plus 125 page, and download the PDF manual․ Additionally, the 3M mobile app offers digital versions of these resources, ensuring easy access to instructions, troubleshooting tips, and maintenance advice for optimal device performance․
9․3 Frequently Asked Questions (FAQs)
- How long does the Prevena Plus 125 Therapy Unit last? It is designed for up to 7 days of continuous use on closed surgical incisions․
- What does the Visicheck feature indicate? It provides a visual confirmation of negative pressure levels, ensuring proper therapy application․
- How do I dispose of the unit? Follow local biohazard guidelines and refer to the user manual for safe disposal instructions․
For additional questions, contact 3M technical support at 1-800-275-4524 for assistance․
The Prevena Plus 125 Therapy Unit is an effective tool for promoting wound healing through negative pressure technology․ It is designed to be user-friendly and enhance patient recovery․ Always follow the provided guidelines for optimal results and patient safety․
10․1 Summary of Key Points
The Prevena Plus 125 Therapy Unit is designed for managing closed surgical incisions using negative pressure technology․ It is user-friendly, promoting effective wound healing and reducing complications․ Ensure patient safety by following setup, monitoring, and maintenance guidelines․ Proper disposal of the single-use device is essential for environmental responsibility․ Always adhere to the provided instructions for optimal therapy outcomes․
10․2 Final Tips for Effective Use
Regularly check tubing for kinks and ensure the canister isn’t full․ Adhere to prescribed negative pressure settings and maintain device cleanliness․ Keep the therapy unit upright to prevent fluid backflow․ Encourage patients to follow discharge guidelines and monitor for alarms․ Address any issues promptly to ensure uninterrupted therapy and optimal healing outcomes․
Additional Resources
Access the 3M Prevena Plus 125 mobile app, online tutorials, and community forums for user testimonials and troubleshooting tips to enhance your therapy experience and understanding․
11․1 Mobile App Support
The Prevena Plus 125 mobile app provides convenient therapy management, offering real-time alerts, usage tracking, and access to instructional guides․ Download the app to monitor progress, receive reminders, and view troubleshooting tips․ It also links to FAQs and direct support contact options for seamless assistance․ This app enhances patient engagement and ensures optimal use of the therapy unit․
11․2 Online Tutorials and Videos
Access comprehensive online tutorials and instructional videos for the Prevena Plus 125 Therapy Unit․ These resources provide step-by-step guidance on setup, operation, and troubleshooting, ensuring optimal use․ Videos cover topics like attaching the foam dressing, connecting tubing, and using the Visicheck feature․ They are designed to enhance patient and caregiver understanding, promoting effective therapy management and adherence to instructions․
11․3 Community Forums and User Testimonials
Engage with community forums dedicated to the Prevena Plus 125 Therapy Unit, where users share experiences, tips, and testimonials․ These platforms offer valuable insights into real-world usage, highlighting benefits and addressing common concerns․ Testimonials from patients and caregivers provide emotional support and practical advice, fostering a sense of community and shared understanding of the therapy process․